Q-SWITCHED ND:YAG LASER SYSTEM
LUCAS
&
MLA
Evenly delivered.
Gently applied.
Precisely fragmented.
The World’s First 15Hz × 7-Split Multi-Pulse System
LUCAS
LUCAS LASER
Trusted by aesthetic dermatology clinics across South Korea.
A Trusted Q-Switched Nd:YAG Laser System
Clinic deliveries in South Korea for three consecutive years
No.1
1,000 +
Clinic Installation Track Record

OVERVIEW
Five modes. One device.
Designed for a broad range of pigmented lesions, including solar lentigines, ephelides (freckles), melasma, acquired dermal melanocytosis (ADM), nevus of Ota, café-au-lait macules, post-inflammatory hyperpigmentation (PIH), and tattoos.
With the MLA handpiece, the system also supports skin rejuvenation through acne scar remodeling, pore refinement, and collagen stimulation.
Pigmented lesions
Toning and Skin Quality Improvement
5 PULSE MODES
Five Pulse Modes for Different Treatment Needs
Single pulse mode
Single Pulse
Delivers a single 5 ns ultra-short pulse.
・ Provides the highest peak power,
producing a strong photoacoustic effect.
・Suitable for fragmenting dense pigmented lesions,
tattoos, and other resistant targets.
PTP mode
Photoacoustic Therapy Pulse
5ns pulse x 2 (pulse interval approximately 100µs)
・ Divides each shot into two pulses,
dispersing the energy.
・ Reduces peak power to minimize stimulation under equivalent energy settings,with consideration for hypopigmentation and PIH.
B mode
Multi Pulse
Delivers four split pulses at intervals of approximately 33 µs.
・ Distributes energy across each sub-pulse, further dispersing the peak output.
・ Designed to enhance stability during toning procedures
with gentle stimulation characteristics.
Seven Toning
Split 7 Pulse / Multi-Split Pulse Structure
Delivers seven split pulses in a single shot.
・ World’s first 7-split multi-pulse system,
with a maximum repetition rate of 15 Hz.
・ Delivers high fluence evenly and safely,
with enhanced consideration for inflammatory responses and hypopigmentation.
Revital Toning
Free Running Mode
Long pulse duration of 300 µs (0.3 ms)
・ Enables “Dual Laser Toning” in combination with Q-switched mode.
・ Supports skin tightening, pore refinement,lifting, and rejuvenation through a heat-based mechanism.

WAVALENGTH
Selectively utilizes two wavelengths: 1064 nm and 532 nm.
1064nm
Targets deep pigmentation
Melasma, nevus of Ota, ADM, tattoos, and other indications.
532nm
Targets superficial pigmentation
Solar lentigines, ephelides (freckles), and other superficial pigmented lesions.
※Penetration depth is determined by wavelength.
MULTI - PULSE LUCAS TONING
Designed to minimize pain and downtime.
Divides the energy of each shot into seven pulses, reducing the burden per pulse while delivering energy evenly to the skin.
This enables effective treatment delivery while minimizing pain and downtime.

Basic Handpiece
For standard irradiation of pigmented lesions.
MLA Handpiece
For fractional-like dot irradiation using a microlens array, supporting pore refinement, acne scar remodeling, and collagen stimulation for skin rejuvenation.


CELL MIRROR ── PERFECT TOP HAT MODE
Delivers uniform energy to the skin as a flat, even beam.
LUCAS is equipped with Perfect Top Hat Mode powered by CELL MIRROR technology.
Energy is distributed uniformly across the entire irradiation area, minimizing the formation of hot spots.
This allows even, surface-level targeting of uneven pigmentation, even with soft, low-output irradiation.
● Uniform Irradiation
Reduces energy unevenness and disperses thermal load on the skin.
● Minimizes damage to the epidermis
Avoids peak energy concentration, with consideration for downtime.
● Stable Beam Quality
Maintains consistent beam quality from the beginning to the end of irradiation.

HIGH-SPEED 15HZ
── UP to 15 Hz ──
Speed translates into uniform results.
The repetition rate of Q-switched Nd:YAG laser toning is generally around 10 Hz.
LUCAS delivers high-speed irradiation at up to 15 Hz, approximately 1.5 times faster.
When combined with Seven Toning, it delivers up to 105 pulses per second: 7 split pulses × 15 Hz.
105
PULSES / SEC ── 7-Split Pulse × 15Hz
High-speed multi-pulse delivery with up to 105 pulses per second.
── Uniformity ──
Precise, even layering.
The faster the irradiation rhythm, the more evenly treatment spots can be placed without gaps. The irradiation follows the operator’s hand movement, helping achieve uniform delivery with reduced unevenness.
UNIFORMITY
── Treatment Efficiency ──
More passes within the same treatment time.
High-speed irradiation allows more passes to be layered within the same treatment time.
THROUGHPUT
── Reproducibility ──
Consistent results with reduced variability.
High-speed irradiation enhances uniformity, helping reduce variability in treatment results.
CONSISTENCY
Repetition Rate / Shots per Second
Competitor Products
LUCAS
→ Approximately 1.5 times more shots within the same treatment time.
10Hz
MAX15Hz
Treatment Example: Full-face toning with a total of 5,000 shots.
PTP mode
3,000 shots (15Hz)
Approximately 3 minutes 20 seconds
Seven Toning
1,000 shots (15Hz)
Approximately 1 minute 7 seconds
Revital Toning
1,000 shots (12Hz)
Approximately 1 minute 23 seconds
Total
5,000 shots
Irradiation Time: Approximately 5 minutes and 50 seconds.
※Estimated irradiation time only. Actual irradiation conditions and treatment protocols are determined by the clinical judgment of each clinic.
※“Generally around 10 Hz” refers to the typical repetition rate of Q-switched Nd:YAG laser toning and is not a comparison with any specific product.
CERTIFICATIONS & TRACK RECORD
Global-standard safety and reliability.
MFDS Approved in South Korea
Approved Medical Device in South Korea
FDA 510(k) Clearance
FDA Cleared in the United States
1,000+ Clinic Installations
No. 1 in Deliveries
for Three Consecutive Years

FAQ
Frequently Asked Questions About the Product
Q
What indications can be covered with a single device?
A single device can address pigmented lesions such as solar lentigines, ephelides, melasma, ADM, nevus of Ota, café-au-lait macules, and tattoos, as well as pore refinement, acne scar remodeling, and rejuvenation with the MLA handpiece.
Q
How does 15 Hz high-speed irradiation benefit treatment?
A faster irradiation rhythm allows treatment spots to be layered more precisely and evenly.
By enabling uniform irradiation, it helps achieve the consistent finish expected from laser toning.
It also allows more passes to be delivered within the same treatment time.
Reference: Full-face toning with 5,000 shots can be completed in approximately 5 minutes and 50 seconds.
Q
Is the operation simple?
Simply select the preset for the target lesion, and the system automatically switches between 1064 nm and 532 nm wavelengths.
There is no need for the operator to manually select the wavelength, reducing both the effort required for switching and the risk of setting errors.
Equipped with an auto-preset function, the system consolidates key functions into two handpieces, allowing operators to use them confidently according to the treatment purpose.
SPECIFICATIONS
Product Specifications
Wavelength
1064nm / 532nm
Laser type
Nd:YAG(Q-Switched)
Operating mode
Q-Switched & Free Running Mode
Pulse width
5–10ns(Q-Switched Mode)/ 300µs(Free Running Mode)
Maximum output energy
1064nm:1,200mJ
PTP 1064nm:1,600mJ
532nm:300mJ
Revital 1064nm:3,000mJ
Display
10.2 inch TFT Wide [800×480]
Size
(W)290 ×(H)810 ×(L)700mm
Power supply
220〜240V, 50/60Hz, 1.6KVA
Weight
75kg
Spot size
2〜10mm(1mm Step Adjust)
Repetition frequency
1〜15Hz(1Hz Step Adjust)